  • undefined
  • undefined

External unit detection system

This test system device mainly provides refined solutions for the production of external electronic control boards, covering product quality, operating status, performance parameters, data storage, and information management.

Product consultation:

Detailed description

  1.1 Outdoor Unit Electrical Assembly Online Detection System

  This testing system equipment mainly provides a refined solution for product quality, operating status, performance parameters, data storage, and information management during the production process of outdoor unit control boards.

  Conditions of Use

  Operating time: 24 hours a day

  Ambient operating temperature: -10—45℃, humidity ≤95%

  Operating power supply: 220/380V, 50HZ. Voltage fluctuation range ±10%.

  Relative humidity: 45%~95%; Compressed air: 0.4-0.55MPA

  Technical Parameters

  1. Operating voltage, current, and power of the integrated heating (electric auxiliary heating) and cooling (high, medium, and low wind) system

  Voltage 0-380V, accuracy ±(0.25% of range + 0.25% of reading)

  Current 0-30A, accuracy ±(0.25% of range + 0.25% of reading)

  Power 0-250W/6500W, accuracy ±(0.25% of range + 0.25% of reading)

  2. Output signal detection of compressor, fan, four-way valve, etc.

  3. According to the protocol provided by the manufacturer (variable frequency, remote control), the system can communicate with the indoor unit circuit board, read various monitoring parameters of the indoor unit system through communication, and control the operating status of the unit according to the set steps.

  4. The system manages and monitors the testing process of each testing trolley, collects and saves the test data of each air conditioner, and can query and print the test results by barcode or model.

Serial Number Test Parameters Number of Test Points at Workstation Measurement Range Measurement Accuracy Remarks

1

Voltage

1

0-380V

±(0.25% of range + 0.25% of reading)

 

2

Current

1

0-30A

 

3

Power

1

0.02-6.5kw

 

4

Communication

1

Communication protocol provided by the client

  1.2 Outdoor Unit Operation Room Online Detection System

  Conditions of Use

  Operating time: 24 hours a day

  Ambient operating temperature: -10—45℃, humidity ≤95%

  Operating power supply: 220/380V, 50HZ. Voltage fluctuation range ±10%.

  Relative humidity: 45%~95%; Compressed air: 0.4-0.55MPA

   Technical Parameters

  1. Operating voltage, current, and power of the integrated heating (electric auxiliary heating) and cooling (high, medium, and low wind) system

  Voltage 0-380V, accuracy ±(0.25% of range + 0.25% of reading)

  Current 0-30A, accuracy ±(0.25% of range + 0.25% of reading)

  Power 0-250W/6500W, accuracy ±(0.25% of range + 0.25% of reading)

  2. Inlet and outlet air temperature 0-50 degrees Celsius, accuracy ±0.5 degrees Celsius

  3. High and low pressure of the pipeline system 0-6MPA, accuracy ±(0.5% of range + 0.25% of reading)

  4. Output signal detection of compressor, fan, four-way valve, etc.

  5. According to the protocol provided by the manufacturer (variable frequency, remote control), the system can communicate with the indoor unit circuit board, read various monitoring parameters of the indoor unit system through communication, and control the operating status of the unit according to the set steps.

  6. The system manages and monitors the testing process of each testing trolley, collects and saves the test data of each air conditioner, and can query and print the test results by barcode or model

Serial Number Test Parameters Number of Test Points at Workstation Measurement Range Measurement Accuracy Remarks

1

Voltage

1

0-380V

±(0.25% of range + 0.25% of reading)

 

2

Current

1

0-30A

 

3

Power

1

0.02-6.5kw

 

4

Communication

1

Communication protocol provided by the client

Keywords:

Intelligent Detection Business

the

0.25


Leave a message

Leave your contact information to get a free product quote


%{tishi_zhanwei}%

Note: Please fill in the above information correctly so that we can feedback the processing results to you as soon as possible!