External unit detection system
This test system device mainly provides refined solutions for the production of external electronic control boards, covering product quality, operating status, performance parameters, data storage, and information management.
Detailed description
1.1 Outdoor Unit Electrical Assembly Online Detection System
This testing system equipment mainly provides a refined solution for product quality, operating status, performance parameters, data storage, and information management during the production process of outdoor unit control boards.
Conditions of Use
Operating time: 24 hours a day
Ambient operating temperature: -10—45℃, humidity ≤95%
Operating power supply: 220/380V, 50HZ. Voltage fluctuation range ±10%.
Relative humidity: 45%~95%; Compressed air: 0.4-0.55MPA
Technical Parameters
1. Operating voltage, current, and power of the integrated heating (electric auxiliary heating) and cooling (high, medium, and low wind) system
Voltage 0-380V, accuracy ±(0.25% of range + 0.25% of reading)
Current 0-30A, accuracy ±(0.25% of range + 0.25% of reading)
Power 0-250W/6500W, accuracy ±(0.25% of range + 0.25% of reading)
2. Output signal detection of compressor, fan, four-way valve, etc.
3. According to the protocol provided by the manufacturer (variable frequency, remote control), the system can communicate with the indoor unit circuit board, read various monitoring parameters of the indoor unit system through communication, and control the operating status of the unit according to the set steps.
4. The system manages and monitors the testing process of each testing trolley, collects and saves the test data of each air conditioner, and can query and print the test results by barcode or model.
Serial Number | Test Parameters | Number of Test Points at Workstation | Measurement Range | Measurement Accuracy | Remarks |
1 |
Voltage |
1 |
0-380V |
±(0.25% of range + 0.25% of reading) |
|
2 |
Current |
1 |
0-30A |
|
|
3 |
Power |
1 |
0.02-6.5kw |
|
|
4 |
Communication |
1 |
Communication protocol provided by the client |
1.2 Outdoor Unit Operation Room Online Detection System
Conditions of Use
Operating time: 24 hours a day
Ambient operating temperature: -10—45℃, humidity ≤95%
Operating power supply: 220/380V, 50HZ. Voltage fluctuation range ±10%.
Relative humidity: 45%~95%; Compressed air: 0.4-0.55MPA
Technical Parameters
1. Operating voltage, current, and power of the integrated heating (electric auxiliary heating) and cooling (high, medium, and low wind) system
Voltage 0-380V, accuracy ±(0.25% of range + 0.25% of reading)
Current 0-30A, accuracy ±(0.25% of range + 0.25% of reading)
Power 0-250W/6500W, accuracy ±(0.25% of range + 0.25% of reading)
2. Inlet and outlet air temperature 0-50 degrees Celsius, accuracy ±0.5 degrees Celsius
3. High and low pressure of the pipeline system 0-6MPA, accuracy ±(0.5% of range + 0.25% of reading)
4. Output signal detection of compressor, fan, four-way valve, etc.
5. According to the protocol provided by the manufacturer (variable frequency, remote control), the system can communicate with the indoor unit circuit board, read various monitoring parameters of the indoor unit system through communication, and control the operating status of the unit according to the set steps.
6. The system manages and monitors the testing process of each testing trolley, collects and saves the test data of each air conditioner, and can query and print the test results by barcode or model
Serial Number | Test Parameters | Number of Test Points at Workstation | Measurement Range | Measurement Accuracy | Remarks |
1 |
Voltage |
1 |
0-380V |
±(0.25% of range + 0.25% of reading) |
|
2 |
Current |
1 |
0-30A |
|
|
3 |
Power |
1 |
0.02-6.5kw |
|
|
4 |
Communication |
1 |
Communication protocol provided by the client |
Keywords:
Intelligent Detection Business
the
0.25
More Business
Leave a message
Leave your contact information to get a free product quote