Solution

Solution

Water dispenser heat pump test system


Time:

2025-05-26


This system consists of a water tank control system and a workstation test system. The water tank control system includes an electrical control cabinet and a water tank. The workstation test system includes a computer, test software, an electrical control cabinet, water pipes, a flow control device, and a barcode scanner.

This system consists of a water tank control system and a workstation test system. The water tank control system includes an electrical control cabinet and a water tank. The workstation test system includes a computer, test software, an electrical control cabinet, water pipes, a flow control device, and a barcode scanner.

Operating Conditions

Operating hours: 24 hours a day

Ambient operating temperature: -10—45℃, humidity ≤95%

Operating power supply: 220/380V, 50HZ. Voltage fluctuation range ±10%.

Relative humidity: 45%~95%; Compressed air: 0.4-0.55MPA

 

Applicable Products

Products

Project

Regardless of season

Remarks

Heat pump hot and cold water machine

Ambient Temperature

25±5 degrees Celsius

 

 

Inlet Water Temperature

15-35 degrees Celsius

 

Water System Parameters

Project

Water Flow Rate

Waterway Component Water Resistance Temperature

Water Pressure

Remarks

Parameters

0.5-6m³/h

>85 degrees Celsius

0.2-0.6MPa

Water flow rate and water temperature are adjustable and controllable